HM-101/112/113/122 |
|
HM-101/112/113/122-Series 810-Micro Vickers Hardness Testing Machines Series 810 Features A wide range of test force from 9.807 X10-3N to 9.807N (10gf to 1000gf) is available for measuring a various type of specimens. The load duration can be set in 1 sec increments between 5 and 99 sec*.The minimum reading of indentation is 0.01μm* and allows small indentations to be measured with high precision.*HM-112,HM-113
Up to 3 Objective lenses and 1 or 2 indenters mounted on manual or motorized turret Eyepiece or CCTV Measuring Versions Camera port
Specifications Order No 810-124A 810-126-07A 810-127-01A 810-127-02A 810-969A Model HM-101 HM-112 HM-122 V HM122 V/K HM-113 Image 810-124A_HM-101.jpg 810-126-07A_HM-112.jpg - - HM-113_810-969-04A.jpg Supplied Indenter Vickers Vickers Vickers Vickers/Knoop Vickers Test Force 98.07mN(10g), 245.2mN(25g), 490.3mN(50g), 980.7mN(100g) 1961mN(200g), 2942mN(300g), 4903mN(500g), 9807mN(1000g) 98.07mN(10g), 245.2mN(25g), 490.3mN(50g), 980.7mN(100g) 1961mN(200g), 2942mN(300g), 4903mN(500g), 9807mN(1000g) 98.07mN(10g), 245.2mN(25g), 490.3mN(50g), 980.7mN(100g) 1961mN(200g), 2942mN(300g), 4903mN(500g), 9807mN(1000g) 98.07mN(10g), 245.2mN(25g), 490.3mN(50g), 980.7mN(100g) 1961mN(200g), 2942mN(300g), 4903mN(500g), 9807mN(1000g) 98.07mN(10g), 245.2mN(25g), 490.3mN(50g), 980.7mN(100g) 1961mN(200g), 2942mN(300g), 4903mN(500g), 9807mN(1000g) Test Force Selection Dial Dial Dial Dial Dial Load Control Automatic (loading, duration, unloading) Automatic (loading, duration, unloading) Automatic (loading, duration, unloading) Automatic (loading, duration, unloading) Automatic (loading, duration, unloading) XY Stage Dimensions 100mm 100mm 100mm 100mm 100mm 100mm 100mm 100mm 100mm 100mm XY Stage Travel 25 x 25 25 x 25mm 25 x 25 25 x 25mm 25 x 25 XY Stage Reading min reading 0.001mm 0.001mm 0.001mm 0.001mm 0.001mm Power Turret Manual Manual Motor Drive Motor Drive Manual Measuring microscope reading total magnification 100x, 500x 100x, 500x 100x, 200x, 500x 100x, 200x, 500x 1250x, 250x Filter Eyepiece Min-Max0.2 mm-140 µm Magnification10x TypeMicrometer Drum Min-Max0.01 - 700/140 µm Magnification10x TypeDigital Optical Encoder Min-Max0.01µm-700/350/140 Magnification10x TypeDigital Optical Encoder Min-Max0.01µm - 700/350/140 µm Magnification10x TypeDigital Optical Encoder Min-Max0.01µm-500/100µm Magnification TypeDigital Optical Encoder Load Duration Range 5s/ min 30s/ max s/increment 5s/ min 99s/ max 1s/increment 5s/ min 99s/ max 1s/increment 5s/ min 99s/ max 1s/increment 5s/ min 99s/ max s/increment Max. Specimen Height 3.75in 95mm 3.75in 95mm 3.75in 95mm 3.75in 95mm 3.75in 95mm Max. Specimen Depth 5.91in 150mm 5.91in 150mm 5.91in 150mm 5.91in 150mm 5.91in 150mm Display Function Conversion: Hard: TENS, HS, HBS, HR15N, HR30N, HR45N, HRA, HRD, HRC, HK, HV, OFF Soft: TENS, HR15T, HR30T, HR45T, HRA, HRF, HRB, HRG, HK, HV, OFF OK/NG Judgment Curve correction: 0.01 to 200.00mm Data processing: Number to measurements 2 to 256 data Statistical list: N, Max., Min., Average, Range, High, Low, Good, Over, Under, SD(n-1), SD(n) Conversion: Hard: TENS, HS, HBS, HR15N, HR30N, HR45N, HRA, HRD, HRC, HK, HV, OFF Soft: TENS, HR15T, HR30T, HR45T, HRA, HRF, HRB, HRG, HK, HV, OFF OK/NG Judgment Curve correction: 0.01 to 200.00mm Data processing: Number to measurements 2 to 256 data Statistical list: N, Max., Min., Average, Range, High, Low, Good, Over, Under, SD(n-1), SD(n) Conversion: Hard: TENS, HS, HBS, HR15N, HR30N, HR45N, HRA, HRD, HRC, HK, HV, OFF Soft: TENS, HR15T, HR30T, HR45T, HRA, HRF, HRB, HRG, HK, HV, OFF OK/NG Judgment Curve correction: 0.01 to 200.00mm Data processing: Number to measurements 2 to 256 data Statistical list: N, Max., Min., Average, Range, High, Low, Good, Over, Under, SD(n-1), SD(n) Conversion: Hard: TENS, HS, HBS, HR15N, HR30N, HR45N, HRA, HRD, HRC, HK, HV, OFF Soft: TENS, HR15T, HR30T, HR45T, HRA, HRF, HRB, HRG, HK, HV, OFF OK/NG Judgment Curve correction: 0.01 to 200.00mm Data processing: Number to measurements 2 to 256 data Statistical list: N, Max., Min., Average, Range, High, Low, Good, Over, Under, SD(n-1), SD(n) Conversion: Hard: TENS, HS, HBS, HR15N, HR30N, HR45N, HRA, HRD, HRC, HK, HV, OFF Soft: TENS, HR15T, HR30T, HR45T, HRA, HRF, HRB, HRG, HK, HV, OFF OK/NG Judgment Curve correction: 0.01 to 200.00mm Data processing: Number to measurements 2 to 256 data Statistical list: N, Max., Min., Average, Range, High, Low, Good, Over, Under, SD(n-1), SD(n) Output - RS-232C, SPC, Centronics RS-232C, SPC, Centronics RS-232C, SPC, Centronics RS-232C, SPC, Centronics Main Unit Dimension 16.1x23.6x23.2in 410x600x590mm 16.1x23.6x23.2in 410x600x590mm 16.1x23.6x23.2in 410x600x590mm 16.1x23.6x23.2in 410x600x590mm 16.1x23.6x23.2in 410x600x590mm Display Unit Dimensions 6.5x10.2x4.1in 6.5x10.2x4.1in 6.5x10.2x4.1in 6.5x10.2x4.1in 6.5x10.2x4.1in Mass 92.4lbs 42kg 92.4lbs 42kg 92.4lbs 42kg 92.4lbs 42kg 92.4lbs 42kg Power Supply 120V AC (±10%) 60Hz 120V AC (±10%) 60Hz 120V AC (±10%) 60Hz 120V AC (±10%) 60Hz 120V AC (±10%) 60Hz Power Consumption 20VA 60VA 60VA 60VA 60VA
|
|
|